  • Micromodular hot and cold aisle design

    Micromodular hot and cold aisle design

    Intelligent hot/cold aisle containment with fully enclosed design, combined with dual-source air conditioning and anti-condensation systems to effectively handle high-temperature, high-density scenarios. While advanced cooling systems like chilled water plants and CRAH units play a major role, one of the most effective strategies is much simpler: controlling how air moves through the data hall. Hot aisle and cold aisle containment are foundational concepts in data center design. This method raises the temperature of the air returning to a Computer Room Air Con itioner (CRAC) unit, which allows the unit to operate more eficiently.


  • Seismic Design of Cable Trays in Namibia

    Seismic Design of Cable Trays in Namibia

    This study aims to develop a simple yet efficient performance-based design optimization methodology for cable tray systems in building structures. In the paper, the drift ratio between adjacent supports i.


  • Distribution Box Guardrail Design

    Distribution Box Guardrail Design

    Falls are among the most common causes of serious work related injuries and deaths. Employers are required to provide and install fall protection systems to prevent employees from falling off of overhead pl.


  • How to design a network server rack

    How to design a network server rack

    This article provides a step-by-step guide on building a server rack, covering everything from choosing the right rack to installing servers. Server racks can be customized to fit various purposes, and dimensions are crucial for designing the rack. You can use plastic or metal, and. Creating a rack diagram is an important step to having sustainable good cable management in the network cabinet. Rack Elevation or Server Rack Layout Software are simple tools to plan and document the cabling of your server cabinet. A rack diagram is a visual layout that shows how equipment like servers, switches, patch panels, and power. Create Rack Diagram online, with an online Rack Diagram software Installing equipment in a server rack without prior planning can be problematic since you may not have enough space for the equipment and cables.

    [PDF Version]
  • The installation of the distribution box meets the design requirements

    The installation of the distribution box meets the design requirements

    In this guide, we'll break down everything you need to know to install a distribution box correctly and confidently. Choose the right box based on environment (indoor/outdoor), load capacity, and durability. Check for proper IP/NEMA ratings and material quality. It takes the incoming power and safely distributes it to different circuits throughout your building. According to inspection standards, the permissible vertical deviation for boxes with a height less than 50cm is 1. 5mm, and for boxes 50cm or taller, it is 3mm. ‌ Site selection requirements‌: The distribution box should be installed in an area close to the power supply to reduce. Before starting the installation, finding a proper place for putting the distribution box is crucial, because it largely decides the safety and convenience of maintenance. It performs several central functions: Firstly, it.

    [PDF Version]
  • Relay Protection Virtual Platform Design

    Relay Protection Virtual Platform Design

    This whitepaper, co-authored by Intel and Kalkitech describes the virtual protection relay (VPR) concept – an architecture where software-defined and virtualized platforms are deployed to host the critical circuit protection functions for an advanced and agile grid. We assert that this use of. Edge Analytics the availability of IEC-61850-3 certified servers built for substations and VMware vSphere supporting latency-sensitive workloads in the substation. Modern substations require standardized, flexible, scalable, and secure systems to build a data-driven power grid to improve the local. A Virtual Protection Relay is a protection system implemented entirely in software instead of a physical relay box. We outline virtualizati n technology and the networking aspects using performance benchmarks laid by IEC 61850 standards. Protective relays have evolved steadily over time. Early power systems relied on electromechanical relays, which were later. As the energy sector is confronted with the high penetration of renewable energy sources, one of the key aspects of the grid controls which are put under stress is the grid protection sub-system.

    [PDF Version]
  • Three parameters of circuit breaker relay protection

    Three parameters of circuit breaker relay protection

    Three fundamental components required for each circuit breaker. CT's transform line current down to a signal level that is acceptable to the relay. Protective relays and devices have been developed over 100 years ago to provide “lastline”of defense for the electrical systems. These relays are self-contained & compact devices that detect abnormal conditions occurring within the electrical circuits by measuring the. Protective Relay Definition: A protective relay is an automatic device that senses abnormal conditions in electrical circuits and triggers actions to isolate faults. To understand the phenomenon of Over Voltages and its classification. Apply technology to. This handbook covers the code of practice in protection circuitry including standard lead and device numbers, mode of connections at terminal strips, colour codes in multicore cables, dos and donts in execution.

    [PDF Version]
  • What are the 5 parameters of relay protection

    What are the 5 parameters of relay protection

    Effective relay protection depends on accurate calculations, optimal settings, careful coordination, appropriate selection of relays, and thorough validation. Long term cost reduction (TCO) for trainings and maintenance by reduce variety of relays A fast and selective arc fault mitigation for air-insulated LV & MV switchgear and Relion protection and control relays and sensor. The selection and applications of protective relays and their associated schemes shall achieve reliability, security, speed and properly coordinated. Meanwhile, protective devices have also gone through significant advancements from the electromechanical devices to the multifunctional, numerical. Protective Relay Definition: A protective relay is an automatic device that senses abnormal conditions in electrical circuits and triggers actions to isolate faults.

    [PDF Version]
  • SN Connector Design

    SN Connector Design

    The SN connector is one of the VSFF solutions to increase density for duplex connections. 25 mm fully-ceramic ferrule technology. It belongs to the category of Very Small Form Factor (VSFF) plug connectors. Supporting ultra-high density network designs while delivering carrier‑grade performance and long‑term reliability, the SN® connector allows network operators to increase. Ushering in a new era of dual-fiber connectivity, the new VSFF (Very Small Form Factor) connectors from HUBER+SUHNER provide data center and central office customers with a high-density, space-saving and high performance connector, that addresses space restriction pressure in existing facilities. As switch and transceiver platforms evolved toward 400G and 800G, the. The SN™-MT is a next-generation multi-fiber connector, that carries a maximum of 32 fibers in double rows ferrule contained within a regular SN™ connector footprint. It is suitable for many applications that require.

    [PDF Version]
  • Technical parameters of photovoltaic silica sand

    Technical parameters of photovoltaic silica sand

    High-purity silica sand used for solar glass production must meet stringent technical criteria, particularly in terms of chemical composition. SiO₂ is essential for the formation of high-clarity, low-iron glass. Low iron content minimizes greenish tint and ensures maximum light transmission. Solar-grade silica requires exceptional purity levels, with silicon dioxide (SiO2) content exceeding 99. Q: Can river sand substitute silica sand? A: Absolutely not –. The Fe2O3 in silica sand is reduced to less than 90ppm by flotation with common quartz sand as raw material to meet the quality requirements of photovoltaic glass raw materials. What is glass &. Silica sand (≥99. 5% SiO₂) is prized for its optical clarity, thermal stability, and chemical inertness, making it a cornerstone of solar technology: High-Purity Glass Production: Forms the transparent, tempered glass that protects solar cells while maximizing light transmission. Silicon Ingot. ICM Technology procures premium silica sand from a range of locations, including Australia, India, Malaysia, and Indonesia.

    [PDF Version]
  • Technical parameters for low-loss CE certification of fiber optic fusion splice boxes

    Technical parameters for low-loss CE certification of fiber optic fusion splice boxes

    LC and SC form factor Fusion-Splice Connectors shall be TIA/ EIA-604 FOCIS-3 (for SC) and FOCIS-10 compatible (for LC), and include a pre-polished fiber which eliminates the need for field polishing and adhesives. The most fundamental parameter for optical fiber is geometry, since the dimensions of the fiber determine its ability to be spliced and terminated to other fibers. This guide reveals the secrets to fusion splicing with little fluff—just proven, straightforward techniques refined from years of work in the field. The guide provides the complete workflow, covering safety precautions, tool selection, fiber preparation, fusion operation, quality control, and. Fibre optic CE certification, RoHS compliance, and ISO IEC 11801 form the regulatory foundation for every professional fibre installation in Europe. These three certification standards ensure not only legal compliance of your fibre components, but also define technical minimum requirements for. Typical splice loss values (the measure of loss in optical power across the splice point) are usually lower for fusion splices (typically less than 0. 1 dB) than for mechanical splices (around 0.